*In accordance with ANSI/ASHRAE Standard 62.2-2016
One of the best heat recovery efficiency on the market due to innovative hexagonal structure of the heat exchanger cells. | The specially designed front panel can be closed manually to ensure 100% air tightness and protection against wind. | Easy maintenance. The indoor unit is openedby pressing the latches | Integrated air shutters prevent air back drafting. |
Сeramic energy regenerator
The high-tech ceramic regenerator with heat recovery efficiency up to 93 % is used for heating of supply air by means of the exhaust air heat recovery. Due to its honeycomb structure, the unique heat exchanger has larger air contact area and excellent heat conducting and accumulating properties. The ceramic regenerator has a special anti-bacterial treatment to prevent bacteria generation inside it. The antibacterial treatment is rated for 10 year operation.
Reversible DC motor
Air is supplied or exhausted by a reversible axial fan with DC motor. Due to DC technology the fan has outstanding low energy demand. The fan is powered by safe voltage 12 V. The motor has integrated overheating protection and ball bearings for long service life.
Air filters
The two integrated air filters with total filtration rate MERV 5 provide supply and exhaust air filtration. The filters prevent ingress of dust and insects into the supply air and contamination of the ventilator parts. The filters also have antibacterial treatment. The filter cleaning is done with a vacuum cleaner or water flushing. The antibacterial properties is not removed. MERV 14 filter with the filtration class PM2.5 99 % is available as a specially ordered accessory.*
TwinFresh ventilator functioning
The ventilator is designed both for reversible mode with energy regeneration and supply or exhaust mode with no regeneration.
The ventilator is controlled means of:
Connection of several ventilators via Wi-Fi for synchronous operation. Ventilation control via cloud service worldwide.
Connection to Smart Home or BMS via Wi-Fi.
Lineup Vents TwinFresh Expert RW1-50-2 Wi-Fi | Rated power, W | Maximum unit current, A | Air flow in ventilation mode, CFM | Air flow in heat recovery mode, CFM | Heat recovery efficiency, max, % | Heat exchanger material | CO2 sensor | VOC sensor | Minimum wall thickness, in (mm) |
---|---|---|---|---|---|---|---|---|---|
7.06 | 0.059 | 30 | 15 | 93 | Ceramic | 5 7/8” |