Heat Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air.
  • Sound insulation
  • Motor type: AC

FRIGATE

Heat and Energy recovery ventilators are a complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air.

Main features

Fast and easy mounting due to bracket system

Automatic recirculation damper for pressure neutral frost protection

No drain needed (enthalpy core)

Effective ventilation overcoming high pressure in condo tower duct systems

Sensible Recovery Efficiency

Built-in control board enables supply and exhaust fan independent speed adjustment from 0 to 100% right at the installation site

Filter

  • Washable MERV6 air filters in exhaust and supply air streams.
  • Optional supply: MERV 13 Supply Filter.


Heat/Energy Recovery Core

  • Polystyrene cross-flow core (for heat recovery units) ensures efficient heat recovery.


  • Enthalpy core (for energy recovery units) provides both heat&humidity recovery. No drain required for enthalpy core.


Defrost system

  • Energy efficient frost prevention by pressure-neutral recirculation mode. Defrost system is activated when the outdoor temperature falls below 23° F (-5° C). Recirculation defrost (R option).
  • Fan stop defrost (standard option)


Control

The unit incorporates an integrated automation and control system with following functions:

  • Operation mode switch.
  • Air flow balancing enabled by supply and exhaust fan independent speed adjustment from 0 to 100% (percentage is displayed on built-in screen).
  • Automatic recovery core frost protection.

________

The Frigate ERV/HRV 80/150 EC units are equipped with high efficient electronically commutated motors with an external rotor and impeller with backward curved blades. The EC motors are featured with high performance and total speed controllable range. The electric motors and impellers are dynamically balanced.

________

The Frigate ERV/HRV 80/150 units are equipped with supply and exhaust centrifugal fans with backward curved blades and build-in thermal overheating protection with automatic restart. The electric motors and impellers are dynamically balanced.

________

The Frigate ERV/HRV 120 EC units are equipped with high efficient electronically commutated motors with an rotor and impeller with forward curved blades. The EC motors are featured with high performance and total speed controllable range. The electric motors and impellers are dynamically balanced.

________
The Frigate ERV/HRV 120 units are equipped with supply and exhaust centrifugal fans with forward curved blades and build-in thermal overheating protection with automatic restart. The electric motors and impellers are dynamically balanced.

Constant flow (CF option)
The Frigate units have an automatic constant air flow control function to keep the air flow in supply and exhaust air ducts constant even in case of variable air resistance.

No manual balancing needed!

This function is provided with the integrated air flow control units. The electronic sensors convert the actual air flow to the analogue signal that is proportional to the air flow in the air duct. These signals are transmitted to the controller that controls the rotation speed of a respective fan in such a way that the actual rotation speed is equal to the set value.
Balancing

Manual balancing is a standard balancing system. Fan speed manually adjusted via the built-in control panel with independent fan speed adjustment 0-100%.


Lineup Vents Frigate HRV Minimum performance @0.4", CFM
175
175
162
162
Datasheet
Frigate catalogue 2022-08
9.08 Mb
Datasheet
Frigate HRV 120 AC specification
716 Kb
Datasheet
Frigate HRV 120R AC specification
735 Kb
Datasheet
Frigate HRV 150 AC specification
816 Kb
Datasheet
Frigate HRV 150R AC specification
736 Kb
Manual
Frigate ERV(HRV) 80-100-120-150 (EC) user's manual
4.58 Mb
Manual
Frigate ERV(HRV) 80-100-120-150 (EC) installation guide
620 Kb
Certificates
ETL Certification mark for Frigate, Brig, Micra 60, VUT
133 Kb
Certificates
MET Certification record for Frigate AC
175 Kb
Image
Frigate HRV - image 1
481 Kb