*In accordance with ANSI/ASHRAE Standard 62.2-2016
One of the best heat recovery efficiency on the market due to innovative hexagonal structure of the heat exchanger cells. | The specially designed front panel can be closed manually to ensure 100% air tightness and protection against wind. | Easy maintenance. The indoor unit is openedby pressing the latches | Integrated air shutters prevent air back drafting. |
Ceramic energy accumulator (regenerator)
The high-tech ceramic regenerator with heat recovery efficiency up to 70 % is used for heating of supply air by means of the exhaust air heat recovery. Due to its honeycomb structure, the unique heat exchanger has larger air contact area and excellent heat conducting and accumulating properties.
Reversible DC fan
Air is supplied or exhausted by a reversible axial fan with DC motor. Due to DC technology the fan has outstanding low energy demand. The fan is powered by safe voltage 12 V. The motor has integrated overheating protection and ball bearings for long service life.
Air filters
The two integrated air filters with total filtration rate MERV 5 provide supply and exhaust air filtration. The filters prevent ingress of dust and insects into the supply air and contamination of the ventilator parts. The filters also have antibacterial treatment. The filter cleaning is done with a vacuum cleaner or water flushing. MERV 14 filter with the filtration class PM2.5 99 % is available as a specially ordered accessory.*
* Reduces the air flow down to 40 CFM when installed.
The ventilator is controlled means of:
Connection of several ventilators via Wi-Fi for synchronous operation. Ventilation control via cloud service worldwide.
Connection to Smart Home or BMS via Wi-Fi.
The ventilator is designed for through-the-wall installation inside a prepared hole in an outer wall of the building.
The best ventilation solution is pairwise installation of reverse phase connected ventilators when some units ensure supply of fresh air to the room and the other units exhaust air from the premise. This way the most efficient balanced ventilation is arranged.
In case of brand new construction, the ventilators are mounted in two stages:
Lineup Vents TwinFresh Expert RW1-85-2 V.2 | Rated power, W | Maximum unit current, A | Air flow in ventilation mode, CFM | Air flow in heat recovery mode, CFM | Heat recovery efficiency, max, % | CO2 sensor | VOC sensor | Minimum wall thickness, in (mm) |
---|---|---|---|---|---|---|---|---|
9.68 | 0.106 | 50 | 25 | 70 | 5 7/8” |